Shopping security
The Keithley 2000 Series Scanners are plug-in scanner cards designed to install in the back-panel option slot of Keithley Model 2000, 2001, 2002, and 2010 digital multimeters. Three card variants are available: the 2000-SCAN general-purpose 10-channel card, the 2001-SCAN high-speed multiplexing card with solid-state channels, and the 2001-TCSCAN thermocouple/general-purpose card with built-in cold-junction reference.
These scanner cards transform a host multimeter into a multipoint test and measurement system suited to applications involving up to ten measurement points. Combining scan and measurement capabilities in a single instrument reduces the need for extra equipment, eliminates complexities of triggering, timing, and processing issues, and helps reduce test time. The 2001-TCSCAN supports cold-junction compensated temperature measurements alongside voltage, resistance, and frequency measurements on the same card.
ValueTronics International has supplied new and pre-owned test and measurement equipment from our Elgin, Illinois facility since 1992. Every {{CONDITION}} 2000 Series Scanner card we sell is inspected by our technical staff at our 20,000 square foot warehouse at 1675 Cambridge Drive before it leaves the building. Customers reach a live test equipment specialist by phone and receive the same instrument they were quoted — with the condition, accessories, and documentation confirmed in writing.
Keithley Instruments was founded in Cleveland, Ohio in 1946 and built its reputation on precision low-level electrical measurement instruments. Keithley was acquired by Danaher Corporation in 2010, joining Tektronix in the same portfolio. In 2016, Danaher's industrial businesses — including both Keithley and Tektronix — were spun off into Fortive Corporation, where the Keithley brand continues today.
The Keithley 2000 Series Scanners comprise three plug-in scanner cards — the 2000-SCAN, 2001-SCAN, and 2001-TCSCAN — that all install in the back-panel option slot of the Keithley Model 2000, 2001, 2002, and 2010 digital multimeters. The datasheet groups these three cards as a family because they share the same host-instrument compatibility, the same compact mechanical form factor, and the same screw terminal input architecture.
Within the family, each card targets a different measurement focus. The 2000-SCAN is the general-purpose 10-channel relay scanner. The 2001-SCAN adds two solid-state channels to enable high-speed ratio and delta measurements. The 2001-TCSCAN trades one channel for a built-in cold-junction reference to enable thermocouple temperature measurements alongside voltage, resistance, and frequency.
Each new 2000 Series Scanner card listed below is its own dedicated product page with condition-matched pricing. Click into the specific card variant that fits your application and host multimeter to see the current quote, accessories included, and availability.
The 2000-SCAN is the entry point in the family: 10 channels of 2-pole relay input, configurable as 5-channel 4-pole, suited to general-purpose multiplexing into the host multimeter without the solid-state speed enhancements or thermocouple reference of the other two cards.
The three cards differ in channel architecture and measurement capability. The 2000-SCAN provides ten 2-pole relay channels with no solid-state or thermocouple capability. The 2001-SCAN provides eight relay channels plus two solid-state channels, with the solid-state channels supporting DCV, ACV, and frequency measurements at faster actuation times (150 µs on / 100 µs off versus 2.5 ms for the relay channels). The 2001-TCSCAN provides nine analog channels plus a dedicated cold-junction reference channel for thermocouple work, with scan speeds up to 43 channels per second at 1°C resolution.
Function coverage also differs across the family. The 2001-SCAN relay channels handle DCV, ACV, 4-wire and 2-wire resistance, RTDs, frequency, and (on two channels with user-supplied shunt resistors) DCI and ACI. The 2001-SCAN solid-state channels are limited to DCV, ACV, and frequency. The 2001-TCSCAN supports DCV, ACV, 4-wire resistance, thermocouple, 2-wire resistance, 4-wire RTD, 2-wire RTD, and frequency — mixable channel to channel.
| Model | Channels | Switching Type | Signal Range |
|---|---|---|---|
| 2001-SCAN | 10 (8 relay + 2 solid-state) | Relay + Solid-State Hybrid | 500nV to 125V; 110V DC, 1A (relay); 50mA (solid-state) |
| 2000-SCAN | 10 (2-pole), configurable as 5 (4-pole) | Relay (electromechanical) | Up to 110V DC / 125V AC rms, 1A |
| 2001-TCSCAN | 9 analog input + 1 cold-junction reference | Relay (2-pole) | 500nV to 125V |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Parameter | Specification |
|---|---|
| General — 10 Channels | |
| Relay Channels | 8 channels of 2-pole relay input |
| Solid-State Channels | 2 channels of 2-pole solid-state input |
| Configuration | All channels configurable to 4-pole |
| Capabilities | |
| Mode a | Multiplex one of ten 2-pole or one of five 4-pole signals into DMM and/or any combination of 2- or 4-pole signals |
| Mode b | Two-channel, high-speed multiplexing into the DMM |
| Mode c | High-speed ratio or delta measurements |
| Functions (can be mixed from channel to channel) | |
| Relay Channels | DCV, ACV, 4-Wire Ω, 4-Wire RTD, Frequency; DCI, ACI (on 2 channels, using user-supplied 1/4W shunt resistor); 2-Wire Ω, 2-Wire RTD |
| Solid-State Channels | DCV, ACV, 4-Wire Ω, 4-Wire RTD, Frequency |
| Relay Inputs — Maximum Signal Level | |
| DC Signals | 110V DC, 1A switched, 30VA maximum (resistive load) |
| AC Signals | 125V AC rms or 175V AC peak, 100kHz maximum, 1A switched, 62.5VA maximum (resistive load) |
| Contact Life | >105 operations at maximum signal level; >108 operations cold switching |
| Contact Resistance | <1Ω at end of contact life |
| Actuation Time | 2.5ms maximum on/off |
| Solid-State Inputs | |
| Resistance | <275Ω (including 200Ω series resistor) |
| Maximum Signal Level | 110V DC, 175V peak AC, 50mA, 100kHz maximum |
| Actuation Time | 150µs maximum on, 100µs maximum off |
| All Inputs | |
| Contact Potential | <±500nV typical per contact, 1µV max; <±500nV typical per contact pair, 1µV max |
| Connector Type | Screw terminal, #22 AWG wire size |
| Isolation Between Any Two Terminals | >109Ω, <75pF |
| Isolation Between Any Terminal and Earth | >109Ω, <150pF |
| Common Mode Voltage | 350V peak between any terminal and earth |
| Maximum Voltage Between Any Two Terminals | 200V peak |
| Maximum Voltage Between Any Terminal and Model 2001 Input LO | 200V peak |
| General Conditions | |
| Environmental | Meets all Model 2001 environmental specifications |
| Dimensions | 21mm high × 72mm wide × 221mm deep (0.83 in. × 2.83 in. × 8.7 in.) |
| Weight | Adds 0.4kg (10 oz.) |
| Scanner Configuration | Same as 2000-SCAN |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Ships within 48 hours · Estimated delivery Jun 23 - Jun 28
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order