The Keysight E4416A and E4417A are EPM-P series power meters that operate with the E-series E9320 family of peak and average power sensors for peak, average, and time-gated power measurements. The E4416A is a single-channel instrument, while the E4417A provides two measurement channels. In addition to the E9320 sensors, the EPM-P meters also operate with the 8480 and N8480 series, E-series CW, and the E9300 range of power sensors for average power measurements. Two measurement modes are provided: Normal mode, the default when using E9320 sensors, for peak, average, and time-related measurements; and Average only mode, intended primarily for average power measurements on low-level signals and used with the 8480, N8480, E-series CW, and E9300 sensors.
A power meter quantifies the RF or microwave power present at its sensor input and displays the result in absolute units (watts or dBm) or relative units (percent or dB). The EPM-P series adds predefined setups for common wireless standards — GSM900, EDGE, NADC, iDEN, Bluetooth, IS-95 CDMA, W-CDMA, and cdma2000 — simplifying configuration for those measurement tasks. With a 20 Msample/second continuous sampling rate and a 5 MHz video bandwidth, the system follows the power envelope of an input signal; because that envelope is, in some cases, set by the signal's modulation bandwidth, the video bandwidth is sometimes referred to as modulation bandwidth.
ValueTronics holds and stocks its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, so the instruments offered here are inventory we keep on hand rather than items sourced after the fact. Every used unit is inspected and functionally verified in-house by our technicians before it ships, while new units ship factory-sealed exactly as received. That combination lets engineers and labs source the right power meter and sensor configuration with confidence in both condition and availability.
Keysight Technologies traces its roots to Hewlett-Packard, whose test and measurement business was spun off as Agilent Technologies in 1999 and then established as the independent Keysight Technologies in 2014.
The EPM-P series pairs the E4416A and E4417A power meters with the E-series E9320 family of peak and average power sensors. The E4416A is a single-channel meter and the E4417A is a dual-channel meter; both share the same measurement modes, interfaces, and reference architecture. Measurement capability — frequency coverage, power range, and dynamic range — depends on which sensor is connected.
The E9320 sensors come in six models that differ in frequency coverage and video bandwidth. The E9321A, E9322A, and E9323A cover 50 MHz to 6 GHz, while the E9325A, E9326A, and E9327A cover 50 MHz to 18 GHz, with video bandwidths of 300 kHz, 1.5 MHz, and 5 MHz spanning the pairs.
Each pre-owned model below is its own dedicated product page with condition-matched pricing. Select the meter or sensor that fits your application, and review that page for its specific configuration and availability.
The primary meter difference is channel count: the E4416A provides a single measurement channel, while the E4417A provides two channels and adds a second recorder output for channel B. Net weight differs slightly (approximately 4.0 kg versus 4.1 kg), and the E4417A ships with two E9288A sensor cables versus one for the E4416A.
The series offers channel functions including A, B, A/B, B/A, A-B, B-A, and relative readings. Measurement speed in fast mode differs slightly between the two meters: for a 10 dB decreasing power step within the -50 to +20 dBm range, the settling time is 10 ms for the E4416A and 20 ms for the E4417A.
Across the E9320 sensors, the differences are frequency range and video bandwidth: the E9321A/E9322A/E9323A reach 6 GHz and the E9325A/E9326A/E9327A reach 18 GHz, with video bandwidths of 300 kHz, 1.5 MHz, and 5 MHz respectively. The comparison table that follows details the per-model frequency range, video bandwidth, and power range.
| Model | Type | Frequency Range | Video Bandwidth |
|---|---|---|---|
| E9327A | Power Sensor | 50 MHz to 18 GHz | 5 MHz |
| E4416A | Power Meter | 9 kHz to 110 GHz, sensor dependent | 5 MHz |
| E4417A | Power Meter | 9 kHz to 110 GHz, sensor dependent | 5 MHz |
| E9321A | Power Sensor | 50 MHz to 6 GHz | 300 kHz |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Sensor Specification | |
| Frequency range | 50 MHz to 18 GHz |
| Video bandwidth | 5 MHz |
| Power range (average only mode) | –60 dBm to +20 dBm |
| Power range (normal mode) | –40 dBm to +20 dBm |
| Maximum power | +23 dBm average; +30 dBm peak (< 10 µsec duration) |
| Connector type | Type N (m) |
| Single sensor dynamic range | 70 dB maximum (normal mode); 85 dB maximum (average only mode) |
| Measurement Ranges — Normal Mode | |
| Lower range (min. power) | –40 dBm |
| Lower range (max. power) | –5 dBm |
| Upper range (min. power) | –30 dBm |
| Upper range (max. power) | +20 dBm |
| Auto range point (normal mode) | –15 dBm |
| Measurement Ranges — Average Only Mode | |
| Lower range (min. power) | –60 dBm |
| Lower range (max. power) | –10.5 dBm |
| Upper range (min. power) | –35 dBm |
| Upper range (max. power) | +20 dBm |
| Auto range point (average only mode) | –11.5 dBm |
| Maximum SWR (≦ 0 dBm) | |
| 50 MHz to 2 GHz | 1.14 |
| >2 GHz to 16 GHz | 1.22 |
| >16 GHz to 18 GHz | 1.26 |
| Sensor Linearity | |
| Normal mode (25 ± 10 °C / 0 to 55 °C) | ± 4.2% / ± 5.0% |
| Average only mode (25 ± 10 °C / 0 to 55 °C) | ± 3.7% / ± 5.0% |
| Additional linearity error if temperature changes after calibration (25 ± 10 °C / 0 to 55 °C) | ± 1.0% / ± 1.0% |
| Calibration factor uncertainty adder (power > 0 dBm) | ± 0.2%/dB |
| Zero Set | |
| Normal mode / average only mode | 60 nW / 0.6 nW |
| Zero Drift and Measurement Noise | |
| Zero drift (normal mode / average only mode) | < 40 nW / < 100 pW |
| Measurement noise, normal mode (free run) / normal mode (VBW off, no averaging) / average only mode | < 25 nW / < 550 nW / < 400 pW |
| Measurement Uncertainty (typical, E9323A/E9327A, 5 MHz bandwidth, 25 °C) | |
| –30 to –20 dBm | 0.9% |
| –20 to –10 dBm | 0.8% |
| –10 to 0 dBm | 0.65% |
| 0 to +10 dBm | 0.55% |
| +10 to +20 dBm | 0.45% |
| Rise and Fall Times (Low / Medium / High / Off) | |
| Rise time (< µs) | 0.9 / 0.4 / 0.2 / 0.2 |
| Fall time (< µs) | 0.9 / 0.4 / 0.2 / 0.2 |
| Settling time, rising (< µs) | 4.5 / 3.5 / 1.5 / 0.4 |
| Settling time, falling (< µs) | 4.5 / 3.5 / 2 / 0.4 |
| Physical | |
| Dimensions (L x W x H) | 150 mm x 38 mm x 30 mm (5.9 in x 1.5 in x 1.2 in) |
| Net weight | 0.2 kg (0.45 lbs) |
| Shipping weight | 0.55 kg (1.2 lbs) |
Important: E9320 power sensors must be used with an E9288A, E9288B, or E9288C sensor cable.
Important: A compatible power sensor is required to make measurements and is ordered separately — the EPM-P power meter's standard-shipped accessories include only the power sensor cable, power cord and manuals (no sensor). The EPM-P series operates with the E-series E9320 family for peak/average measurements and with the 8480, N8480, E-series CW and E9300 sensors for average power measurements.
Important: The E9288A, B and C sensor cables will also operate with 8480, N8480 and E-series power sensors.
Important: Rise and fall time specifications are only valid when used with the E9288A sensor cable (1.5 meters).
Important: Calibration service options (R-50C-011-3 / R-50C-011-5) are not available in all countries.
Important: To preserve the EMC performance of the product, any cable which becomes worn or damaged must be replaced with the same type and specification.
This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Ships within 48 hours · Estimated delivery Jun 23 - Jun 28
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order